Product Description

Dental Dark Room X-ray Film Processor Manual Dark Chamber

Feature:

  •  Processing in light room
  • Simple and convenient
  •  
  • Get clear image than other method
  •  
  • Can be implemented when space is limited

    Installment Introduce:

    1. Put the pocket-sized darkroom on the desk...
    2. Open the lid of the pocket-sized darkroom.
    3. Put the three cups, developing solution(A), fixer solution (B), clear water (C), into the three holes on the foundation, and please sign them by yourself.
    4. Open the cover of cup A, B and tear the seal membrane and return the original position, the solution of the cup (C) is Clear Water.
    5. Hang the clamped-pieces on the steel wire in the socket-sized dark-room
    6. Cover the lid and you can use the socket-sized darkroom

    Using method:

    1. Determines the temperature of the developing solution (A) with the thermometer.
    2. Enter the two hands into the socketsized darkroom from the two holes and tear the bag of the photographic film and take out the film, clamp the film.
    3. According to the developing time on developing solution(A)(or determine the developing time according to everyone's developing experience).
    4. Plunge the clamp with film into developing solution (A) right now, mix about10 sec, and hang them on the side of the cup 2-5min.
    5. Then plunge the clamp with film into fixer solution (B), mix about 10sec, and hang them on the side of the cup 2-4min. By the film for thorough fixer
    6. Plunge the clamp with film into clear water (C), rinsing about 10 min. (if you want to see the result, you can look at the wet film under the lamp)
    7. At last hang the film on the clean place, blow or drying, archive.
    name     Dental X-ray Film Processor
    Certification    CE

    Attention:

    1. If the above solutions are you matching by your own or buy from other company, you should adjust the above parameters in order to guarantee the quality
    2. In order to avoid to appearing the fingerprint or the damage on the film, you should operate carefully
    3. If the film falls into the developing solution(A), you should take out it guard against the affect too black.
    4. Cover the lid when you don't use the darkroom, in order to delay the using time.
    5. In order to receiving the high quality image, as usual after using 15 days or developing 150PCS films, change the solution. After tearing the seal membrane, the validity of the solution is 30days.
    6. If the solution of A, B splash into eyes, you should clean with clear water right now.
    7. The material of the lid of the socket-sized darkroom is light guide material, the price is expensive, please protect carefully, guard against burst.
Payment Terms︰T/T, L/C, CASH, WESTERN UNION .
Product Image





Related Products
High Quality Mobile X Ray Machine Moving Type Dental X Ray Unit
High Quality Mobile X Ray Machine Moving Type Dental X Ray Unit
US $ 650
 Wall Hanging Digital Dental X-ray Unit Machine
Wall Hanging Digital Dental X-ray Unit Machine
US $ 650
Portable Handheld Dental X-ray Machine Unit Digital Control
Portable Handheld Dental X-ray Machine Unit Digital Control
US $ 1150
Dental X-ray Film Processor Automatic Dark Room
Dental X-ray Film Processor Automatic Dark Room
US $ 400




Home  |  Product Catalog  |  News  |  Contact Us  |  Sitemap  |  Mobile Version

Powered by DIYTrade.com  Build your FREE website !
Find Best Price For China Products !